{"id":56862,"date":"2021-12-20T13:46:24","date_gmt":"2021-12-20T12:46:24","guid":{"rendered":"http:\/\/www.elea.si\/portfolio\/hotel-intercontinental-ljubljana\/"},"modified":"2024-07-26T14:54:55","modified_gmt":"2024-07-26T12:54:55","slug":"hotel-intercontinental-ljubljana","status":"publish","type":"portfolio","link":"https:\/\/www.elea.si\/en\/portfolio\/hotel-intercontinental-ljubljana\/","title":{"rendered":"Hotel InterContinental"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>The hotel Intercontinental was erected at the end of 2017. Its above-ground height of 82 m made it the second-highest business\/residential building in Slovenia. The erection of the building having 4 subterranean stories and 22 above-ground stories progressed extremely rapidly despite a very confined building site at the intersection of Slovenska and Tivolska roads in Ljubljana. Since the starting project phase, the micro-location of the building had a decisive impact on the architectural design of the building and consequently on the carrying structure design.<br \/>\nThe reinforced-concrete construction of the building was erected on improved foundation ground in a 13 m deep open construction pit protected by multi-anchored secant piles. The execution of smooth, subsequently stressed reinforced-concrete slabs allowed the execution of longer console projections of stories, a more lightweight and slender structure, and more rapid work progress. The building has high earthquake safety due to the arrangement of a reinforced-concrete wall core in the center of the ground plan and due to circumferential columns. <\/p>\n","protected":false},"author":1,"featured_media":59111,"parent":0,"menu_order":93,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"portfolio_category":[92,95,167,169,170,171,176],"class_list":["post-56862","portfolio","type-portfolio","status-publish","has-post-thumbnail","hentry","portfolio_category-structural-engineering","portfolio_category-featured","portfolio_category-energy-efficiency-and-renewable-energy-sources","portfolio_category-providing-access-for-the-disabled","portfolio_category-impact-on-the-wider-economy","portfolio_category-bim-technologies","portfolio_category-charging-stations-for-electric-vehicles"],"_links":{"self":[{"href":"https:\/\/www.elea.si\/en\/wp-json\/wp\/v2\/portfolio\/56862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.elea.si\/en\/wp-json\/wp\/v2\/portfolio"}],"about":[{"href":"https:\/\/www.elea.si\/en\/wp-json\/wp\/v2\/types\/portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/www.elea.si\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.elea.si\/en\/wp-json\/wp\/v2\/comments?post=56862"}],"version-history":[{"count":5,"href":"https:\/\/www.elea.si\/en\/wp-json\/wp\/v2\/portfolio\/56862\/revisions"}],"predecessor-version":[{"id":64516,"href":"https:\/\/www.elea.si\/en\/wp-json\/wp\/v2\/portfolio\/56862\/revisions\/64516"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.elea.si\/en\/wp-json\/wp\/v2\/media\/59111"}],"wp:attachment":[{"href":"https:\/\/www.elea.si\/en\/wp-json\/wp\/v2\/media?parent=56862"}],"wp:term":[{"taxonomy":"portfolio_category","embeddable":true,"href":"https:\/\/www.elea.si\/en\/wp-json\/wp\/v2\/portfolio_category?post=56862"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}